title: "Data driven safety and incident investigation: Cat 793 rollback root cause in 24 hours"
url: https://maxmine.com.au/case-studies/data-driven-safety-and-incident-investigation/
canonical: https://maxmine.com.au/case-studies/data-driven-safety-and-incident-investigation/
description: "MaxMine produced a black-box style investigation report within 24 hours of a laden Cat 793 stall and rollback, finding a loose ECU wire that caused intermittent fuel loss lasting a tenth of a second."
page_type: case-study
product: IMPACT
author: ""
updated: 2026-11-04
last_reviewed: 2026-11-04
status: v2-draft
faq: true
site_type: "Open pit mine running Cat 793 haul trucks (site not named)"
customer_named: false
headline_result: "Root cause found in a black-box style report within 24 hours of notification: loose ECU wire"
period: "not stated"
modules: [ "IMPACT Safety", "IMPACT Equipment Health" ]
---

# Data driven safety and incident investigation

**Quick answer:** After a fully laden Cat 793 stalled and rolled back on an incline, MaxMine analysts produced a black-box style investigation report within 24 hours of being notified. It found a loose ECU wire causing intermittent fuel loss lasting a tenth of a second, which OEM and site tools had not shown. Site not named.

**Key results**

- **Report within 24 hours** of MaxMine being notified.
- **Root cause: a loose ECU wire** causing intermittent fuel loss of a tenth of a second, with no fault codes or alerts raised by the machine.
- **Fleet check:** the same algorithm confirmed the fault was not present on other equipment.
- **No injuries.** The truck rolled back at up to 17.5 km/h before hitting a windrow.

## What happened on site?

The engine of a fully laden Cat 793 stalled on an incline and the truck sat still for 2.5 minutes. It then rolled backwards, reaching a maximum speed of 17.5 km/h before it hit a windrow and stopped. No one was injured.

## What was the problem?

Existing OEM and site diagnostic tools registered no fault codes at the time of the incident, and the machine raised no alerts. That left the root cause unclear, which made it hard to put measures in place to prevent a repeat. Because of the severity, the mine's inspector closed the operation until the site could show the rest of the fleet was not prone to the same problem.

## What did MaxMine do?

MaxMine engineers used MaxMine algorithms on the truck's high-resolution data to produce a black-box style incident investigation report within 24 hours of being notified. The report identified a loose wire on the ECU as the root cause.

## Results

| Outcome | Detail | Basis |
|---|---|---|
| Time to report | Within 24 hours of MaxMine being notified | As reported in the MaxMine case study |
| Root cause | Loose ECU wire causing intermittent fuel loss lasting a tenth of a second | MaxMine analysis |
| Maintenance | Crews were told what the fault was and why it occurred | As reported |
| Prevention | Management and site crews put measures in place to avoid similar incidents | As reported |
| Fleet check | The same algorithm confirmed the fault did not exist on other equipment | As reported |

## How was it measured?

MaxMine records machine data at a much finer time resolution than the fault codes available to the site. That made it possible to see a fuel loss lasting a tenth of a second. The page does not describe the exact signals used.

## Limits of the result

- The page does not give the date, the site, the duration of the shutdown or how long the inspector's closure lasted.
- It does not state how many machines were checked to confirm the fault was not on other equipment.
- No cost or production figures are given.
- The page does not say how the wire fault was repaired or confirmed by the site.

## Which MaxMine products were used?

- MaxMine IMPACT Safety module: formal investigation reports by MaxMine analysts, as a service. MaxMine does not offer cameras or collision avoidance.
- MaxMine IMPACT Equipment Health module: machine data used to find the fault and check the fleet.

## Frequently asked questions

**How can MaxMine see a fault that lasted a tenth of a second?**
MaxMine records machine data at a much finer time resolution than the fault codes available to the site. The case study does not list the exact signals used.

**Why did the site need an investigation?**
OEM and site diagnostic tools registered no fault codes, and the mine's inspector closed the operation until the site could show the rest of the fleet was not prone to the same problem.

**Is an investigation report part of MaxMine IMPACT Safety?**
MaxMine IMPACT Safety includes formal investigation reports by MaxMine analysts, delivered as a service. MaxMine does not offer cameras or collision avoidance.

**Was the site named?**
No. The case study describes an open pit mine running Cat 793 haul trucks, with no date given.

## Related

- [IMPACT Safety](/solution/safety.md)
- [IMPACT Equipment Health](/solution/equipment-health.md)
- [Analysis and support for safety investigation](/case-studies/analysis-support-for-safety-investigation.md)
- [Fixing an under-performing truck of 2 years](/case-studies/fixing-an-under-performing-truck-of-2-years.md)
- [All case studies](/case-studies/index.md)

## Contact

Talk to MaxMine: https://maxmine.com.au/contact/

*Updated 4 November 2026 by.*